Chapter 6 Alarms and Events

Buffer Module Alarms and Events

Buffer Module Alarms and Events
Table 6-36
lists the alarms and events for the RS422 Output module, and includes
the typical response for each alarm or event, it's event number, and a description or
a suggested corrective action. The SNMP MIB trap is listed in the Alarm/Event/Trap
Description column.
Table 6-36. Buffer Module Alarm and Event Messages
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
000
Pwr-A, Lost
001
Pwr-B, Lost
129
Install, Buffer Module
130
Remove, Buffer Module
251
Err Delay, (0), 300 sec,
COML
252
Alm Level, (0), Maj, COML
253
Elevate Time, 86400 sec,
COML
334 SSU-2000 Technical Reference
Corrective Action
Verify that the fuse for Power A is properly installed and not
OPEN.
Verify that Power Bus A is providing –48 VDC to the unit. If no
power is connected to the Power A input and there is no plan to
connect power, issue the command
prompt.
Verify that the fuse for Power B is properly installed and not
OPEN.
Verify that Power Bus B is providing –48 VDC to the unit. If no
power is connected to the Power B input and there is no plan to
connect power, enter the command AL 10-1 IG at the prompt.
Module Installed.
Module Removed.
User has changed the error delay time.
User has changed the level of specified alarm.
User has changed the alarm elevation time.
Description/
AL 10-1 IG
12713020-003-2 Revision F.01 – January 2007
at the