Symmetricom SSU-2000 Technical Reference page 302

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Chapter 6 Alarms and Events
Communication Module Alarms and Events
Table 6-7. Basic +SNMPv3 and Basic +NTP + SNMPv3 Communications Module Alarm and Event Messages
(Continued)
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
151
UTC Time, Valid
152
TODSYNC, Timeout
153
Upload Image, Start
154
Upgrade, 1A02
155
Upgrade ACK, 1A02
156
Upgrade NAK, 1A02
157
Config, 1A06, Not Support
158
NTP Mode, GPS
159
Reset, Clk-B, COML
160
Clk-C Source, 1A04-01
161
Sync Clk-C, Start
192
InitUserTable, JAY, COML
193
Add User, DONNA, COML
194
Mod User, CALEB, COML
195
Del User, TEST1, COML
196
Pql Table, DS1, pql(5)=ST2,
COML
197
Pql Factory Dflt, COML
198
Unit Name, , COML
199
NTP Peer Add, 192.5.41.
40, CLIENT, COML
200
NTP Peer Del, 192.5.41. 40,
COML
201
NTP Brd Timer, 64 seconds,
COML
202
SNMPv2 User, ADD, id=1,
COML
203
SNMP Agent, V2, COML
302 SSU-2000 Technical Reference
Corrective Action
Time of startup; NTP is enabled but GPS time not being used.
Time of day (TOD) was requested by the Comms module, no
response from the GPS module.
System firmware upgrade status.
Module's firmware upgrade has started.
Module's firmware upgrade was completed.
Module's firmware upgrade was not completed.
Call Symmetricom Global Services. Return to factory.
The SSU is configured with NTP running in an NTP Client,
Broadcast, or Broadcast Client server mode; Local is displayed
when NTP server is initialized. If GPS is not installed or setup, or
NTP has not been configured NTP remains in Local mode and uses
Comms module time.
The clock listed was reset by a user.
Bypass clock source has changed.
Status of Sync acquire operation.
Administrator initialized user database.
Administrator added a user to user database.
User/Administrator modified user database.
Administrator deleted user from user database.
PQL database has been modified.
PQL database has been set to factory defaults.
The SSU name has been changed.
An NTP client was added at the IP address shown.
An NTP client was deleted at the IP address shown.
The NTP broadcast server timer has been set to the interval shown.
An SNMP user has been added to the user table in the position
shown.
The SNMP mode has been enabled.
Description/
12713020-003-2 Revision F.01 – January 2007