Retrieve Ds1/E1 Output Parameters - Symmetricom SSU-2000e Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000e:
Table of Contents

Advertisement

Chapter 2 TL1 Reference

Retrieve DS1/E1 Output Parameters

Retrieve DS1/E1 Output Parameters
This command returns the DS1 or E1 Output module or port settings specified by
the aid.
Syntax
RTRV-PRMTR-OUTPUT:[tid]:[aid]:ctag;
Parameter
[aid]
Response Format
When the aid specifies a port, the response is:
^^^"aid:mode,level,bypass,zs,crc,bit,pstate,len" <cr lf>
where:
= port access identifier
aid
= output signal mode [ESF | D4 | CCS | CAS]
mode
= minimum clock level to enable outputs on the module [ACQ | LOCK]
level
= allow Clock C selection [ON | OFF]
bypass
= zero suppression [ON | OFF]
zs
= error checking [ON | OFF]
crc
= SSM bit [4 – 8] for E1 sync status messages
bit
= port enabled state [ON | OFF]
pstate
= line length setting in feet [133 | 266 | 399 | 533 | 655] for DS1 outputs
len
When the aid specifies a module, the response is:
^^^"aid:mode,level,bypass,zs,crc,bit" <cr lf>
^^^"aid:pstate1,pstate2,...pstate20" <cr lf>
^^^"aid:len1,len2,len3,...,len20" <cr lf>
where:
Line 1 contains:
= module access identifier
aid
= outputs signal mode: [ESF | D4 | CCS | CAS]
mode
= minimum clock level to enable outputs on the module [ACQ | LOCK]
level
52
SSU-2000e Technical Reference
Value
Retrieves the parameters from all DS1 or E1 Output
ALL
modules in the shelf.
Retrieves parameters from the specified DS1 or E1
SxAy[-z]
Output module [or port].
Description
12713140-003-2 Revision E.01 – January 2007

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdu-2000e

Table of Contents