Chapter 2 TL1 Reference

Set Communication Parameters

Set Communication Parameters
This command allows you to set the parameters for the serial communications
ports. Use this command to choose between the ICS and TL1 command mode.
Syntax
SET-PRMTR-COMM:[tid]:[aid]:ctag::[baud],[echo],[eol], [mode],[tout];
Parameter
aid
baud
echo
eol
mode
tout
Empty fields leave parameters unchanged.
Related Commands
Retrieve Communication
140 SSU-2000 Technical Reference
Format
Sets the parameters for the specified communications
ALL, COML,
port.
COMA, COMB,
TELNET, or
TL1
Sets the communications baud rate for the specified port.
19200|9600
|4800|2400
|1200
Sets the unit to use full (On) or half duplex (Off).
ON | OFF
Sets the end-of-line character(s) sent by the unit .
CR | LF |
CRLF
Sets the mode of communication.
ASCII |
TL1
Sets the inactivity timeout period in seconds.
5 – 43200
| NEVER
Parameters, on page 48
Description
12713020-003-2 Revision F.01 – January 2007