Chapter 3 ICS Command Reference
SETUP
USER
SAVE
CONNECTION FACTORY
Note: Restore the user list to factory settings by using the
INITUSERTABLE
Level 4
Same as Level 3 operation
Remarks This command provides a way for the unit to save default settings that
the user prefers for operation. The target module restores user defaults
in the event that current nonvolatile RAM information in the target
module is lost.
If user information is not present, or unusable, the target module
restores the current factory settings. If the factory settings are also not
usable, the software initializes non-volatile RAM with the current
program defaults and transfers those setting into non-volatile RAM as
the new factory settings.
Related
INPUT, CLK, OUTPUT, EVENTS,
RestrictionsNone
244 SSU-2000 Technical Reference
Use this option to restore the current setting to the
previously-saved user setting. If addressed as COMM,
connection and user list are not included.
Use this option to save the current setting as the user
setting. If addressed as COMM, connection and user list
are not included.
Use this command to restore the current connection
configuration in the Communications module.
command.