Chapter 3 ICS Command Reference
OUTPUT
SQUELCH
FREQUENCY
SINE
400HZ
PQL
Level 4
Same as Level 3 operation
Remarks None
Related
ALARM, ELEVTIME, SETUP,
RestrictionsNone
232 SSU-2000 Technical Reference
Turns the output on or off depending on the current PQL
and the threshold. 0 disables the squelch. For 2048 kHz
and E1/2048 kHz Output modules.
Sets the output frequency, starting at 8 kHz and
incrementing 8 kHz per step, to 4096 kHz. For RS-422
Output module.
Sets the output frequency. For Japan Sine Output module.
Control the 400Hz BPV Removal. A setting of OFF
removes this 400Hz components, and a setting of ON
includes it. For JCC Output module.
PQL override (1-16). If zero, PQL override is disabled. For
2048, E1-2048, E1, and DS1 Output modules.
STATUS
12713020-003-2 Revision F.01 – January 2007