Chapter 6 Alarms and Events

DS1/E1 Input Module Alarms and Events

DS1/E1 Input Module Alarms and Events
Table 6-10
lists the alarms and events for DS1/E1 Input modules (1 port and 3 port),
and includes the typical response for each alarm or event, it's event number, and a
description or a suggested corrective action. The SNMP MIB trap is listed in the
Alarm/Event/Trap Description column.
DS1/E1 Input module alarms.
Table 6-10. DS1/E1 Input Module Alarm and Event Messages
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
000
LOS, Active
001
AIS, Active
002
OOF, Active
003
BPV, Active
004
CRC, Active
005
MTIE/L1, Exceeded
006
MTIE/L2, Exceeded
007
PQL, Below Prov
008
SSM, Lost
009
Ref Qualifier, Fault
010
Clock PLL, Unlocked
011
Input PLL, Unlocked
012
Phase Hdw, Fault
013
FREQ, Exceeded
014
Hdw Config, Fault
129
Install, DS1/3P Input Module
130
Remove, DS1/3P Input
Module
131
Enable, Input Module, COML
132
Disable, Input Module, COML
133
Restart, in 5 seconds, COML
306 SSU-2000 Technical Reference
Table 6-11
Corrective Action
Verify signal is connected. To extinguish, disable port.
Verify input signal is good. Port can be disabled.
Change frame type:
DS1–ESF or D4
E1–CAS or CCS
Verify port ZS is on. Verify signal is good.
Verify port CRC is off. Verify signal is good.
MTIE limit 1 has been exceeded.
MTIE limit 2 has been exceeded.
Received SSM (PQL) is below provisioned PQL.
Set port SSM to Off to clear.
Re-seat module, or correct the input signal to clear the fault.
Re-seat module.
Verify input frequency setting. Re-seat module.
Re-seat module.
Input frequency greater than threshold. Monitor frequency; if
persistent, check source.
Input module can be installed only in the Main shelf.
If module is installed in slot previously used by a different module
type, use the CONF xAy REMOVE command.
If problem persists, call Symmetricom Global Services
The Input module has been installed.
The Input module has been removed.
The Input module has been enabled.
The Input module has been disabled.
Module re-boot.
lists the default parameters for the
Description/