Chapter 2 TL1 Reference

Set DS1/E1 Input Parameters

Set DS1/E1 Input Parameters
This command sets the parameters for the specified DS1 or E1 Input module or
port.
Syntax
SET-PRMTR-INPUT:[tid]:[aid]:ctag::[pstate],[pri],[pql],[mode],[ssm],
[zs],[crc],[gain],[csflt],[bit];
Parameter
aid
pstate
pri
pql
mode
ssm
zs
crc
gain
csflt
bit
Empty fields leave parameters unchanged.
Related Commands
Retrieve DS1/E1 Input
142 SSU-2000 Technical Reference
Format
Sets the parameters for the specfied DS1 or E1 Input
S1Ay[-z]
module [or port].
Turns the specified module [or port] on or off.
ON | OFF
Sets the Priority for the specified module [or port]; MON =
1 - 10 |
Monitor.
MON
Sets the Priority Quality Level for the specified module [or
1 - 16
port].
Sets the framing mode or clock frequency in MHz. A
ESF | D4 |
DENY with ICNV message is returned if the mode setting
CCS |CAS |
does not match the module type (DS1 or E1).
1 | 1.544
| 2.048 |
If mode is set to a framed type then frequency is set to
5 | 10
correct frequency for type DS1 (1.544) or E1 (2.048).
Sets the specified module [or port] to read or ignore
ON | OFF
incoming Sync Status Messages.
Enables or disables zero suppression
ON | OFF
For DS1: On = B8ZS, Off = AMI
For E1: On = HDB3, Off = AMI
Enables or disables error checking.
ON | OFF
When set to ON, 20 dB gain is applied to the input signal.
ON | OFF
SSM, zs, crc, and gain are ignored for clock modes.
Sets the external Cesium fault alarm input.
HI | LO |
OFF
Sets the bit number of the Time Slot 0 word used for the
4 - 8
E1 SSM. For DS1 input, the bit value is ignored.
Parameters, on page 51