Chapter 2 TL1 Reference

Retrieve Input Data

Retrieve Input Data
This command returns the current LOS, AIS, OOF, BPV, CRC Error and Clear
counts for the specified inputs on DS1, E1, or CC Input modules.
Syntax
RTRV-DATA-INPUT:[tid]:[aid]:ctag;
Parameter
[aid]
Response Format
When the aid specifies a port, the format for each response message line is:
^^^"aid:loserr,losclr,aiserr,aisclr,ooferr,oofclr,bpverr,bpvclr,
crcerr,crcclr"<cr lf>
where:
= module or port access identifier
aid
is the erred second count for each of the signal faults as listed above
???err
is cleared second count for each of the signal faults as listed above
???clr
When the aid specifies ALL, the format of the response message is:
^^^"aid:LOS,loserr,losclr"<cr lf>
^^^"aid:AIS,aiserr,aisclr"<cr lf>
^^^"aid:OOD,ooferr,oofclr"<cr lf>
^^^"aid:BPV,bpverr,bpvclr"<cr lf>>
^^^"aid:CRC,crcerr,crcclr"<cr lf>
where:
is the erred second count for each of the signal faults as listed above
???err
is cleared second count for each of the signal faults as listed above
???clr
Related Commands
Retrieve Signal Fault Alarm
Set Signal Fault Alarm
72
SSU-2000 Technical Reference
Value
Retrieves the current input data from all modules that are
ALL
currently active in the entire shelf.
Retrieves the current input data from the specified module
S1Ay[-z]
[or port].
Parameters, on page 116
Parameters, on page 172
Description
12713020-003-2 Revision F.01 – January 2007