Chapter 6 Alarms and Events

Japan Sine Output Module Alarms and Events

Japan Sine Output Module Alarms and Events
Table 6-32
lists the alarms and events for the Japan Sine Output module, and
includes the typical response for each alarm or event, it's event number, and a
description or a suggested corrective action. The SNMP MIB trap is listed in the
Alarm/Event/Trap Description column.
Japan Sine Output module alarms.
Table 6-32. Japan Sine Output Module Alarm and Event Messages
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
000
Hdw Config, Fault
001
Configuration, Fault
002
Clk-A, Fault
003
Clk-B, Fault
004
Clk-C, Fault
005
Clk-D, Fault
006
Clk Selected, Fault
007
VCXO, Fault
008
PLL, Fault
009
Redundant, Fault
010
Squelch, Fault, 40000
011
PortFlt, Fault, 40000
129
Install, J/SW Output Module
130
Remove, J/SW Output
Module
131
Enable, J/SW Output
Module, COML
132
Disable, J/SW Output
Module, COML
133
Restart, in 5 seconds, COML
134
Cannot Enable, J/SW
Output Module, COML
194
Port Cntl, Port[1-20],
Enable, COML
330 SSU-2000 Technical Reference
Table 6-33
Corrective Action
Call Symmetricom Global Services. Return to factory.
Redundant configuration mismatch. Re-seat or replace module.
Clock module in slot A1 is in warm-up mode or has other problems.
Clock module in slot A12 is in warm-up mode or has other
problems.
Reference signal is in LOS and both clocks have been removed or
are in warm-up.
Only in SDU. Loss of backup clock. Check cable.
No clocks, no output.
VCXO problems, re-seat or replace module.
No clocks or VCXO. Re-seat and check clocks.
Failed to sync with master module in redundant pair.
PQL is below provisioned value.
Indicates which output port is in fault (typically shorted). Repair
short and re-enable port.
Module Installed.
Module Removed.
Module Enabled.
Module Disabled.
User request for a module to reboot.
Cannot enable module due to configuration error.
User has enabled the specified port.
lists the default parameters for the
Description/
12713020-003-2 Revision F.01 – January 2007