2048 Khz Output Module Default Settings; 2048 Khz Output Module Configuration - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Table 8-10. DS1 and E1 Output Module Default Settings (Continued)
Setting
Enable/Disable Outputs
Minimum Clock Level
Bypass Mode
Framing
CRC
SSM Bit Selection

2048 kHz Output Module Default Settings

The 2048 kHz Output module maintains factory default and current user
configuration settings. The configuration settings for the 2048 kHz Output Module
are provided in
Table 8-11. 2048 kHz Output Module Configuration
Setting
Port State
Min Clock
Framing
Bypass
Fault Action
Alarm Elevation Time
Squelching
12713020-003-2 Revision F.01 – January 2007
Factory
Default
E1 Output Module
Enabled
Settable for each output port
Acquire
Acquire/Lock
ON
ON – Clock C is selected if it is the only one available
OFF – Clock C will not be selected even if no other
clock is available
CAS
CCS/CAS
ON
ON/OFF
8
4 | 5 | 6 | 7 | 8
Table
8-11.
Factory Default
Enabled
Acquire
Not applicable
On
On
86 400 s
0
Chapter 8 Default Settings
2048 kHz Output Module Default Settings
Range
Range
Disabled | Enabled
Acquire | Lock
Not applicable
On | Off
Off | On | Auto
60 to 500 000 s, 0 is disabled
1 to 16, 0 is disabled
SSU-2000 Technical Reference 357