Chapter 6 Alarms and Events

E1/2048 kHz Output Module Alarms and Events

E1/2048 kHz Output Module Alarms and Events
Table 6-28
lists the alarms and events for the E1/2048 kHz Output module, and
includes the typical response for each alarm or event, it's event number, and a
description or a suggested corrective action. The SNMP MIB trap is listed in the
Alarm/Event/Trap Description column.
E1/2048 kHz Output module alarms.
Table 6-28. E1/2048 kHz Output Module Alarm and Event Messages
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
000
Hdw Config, Fault
001
Configuration, Fault
002
Clk-A, Lost
003
Clk-B, Lost
004
Clk-C, Lost
005
Clk-D, Lost
006
Clk Selected, None
007
VCXO, Lost
008
PLL, Unlocked
009
Sync, Fault
010
Squelch, Below Prov, 40000
011
PortFlt, Active, 40000
129
Install, E1/2048 Output
Module
130
Remove, E1/2048 Output
Module
131
Enable, E1/2048 Output
Module, COML
132
Disable, E1/2048 Output
Module, COML
133
Restart in 5 seconds, COML
134
Cannot Enable, E1/2048
Output Module, COML
326 SSU-2000 Technical Reference
Table 6-29
Corrective Action
If module is installed in slot previously used by a different module
type, use the CONF xAy REMOVE command.
If problem persists, call Symmetricom Global Services
Redundant configuration mismatch. Re-seat or replace module.
Clock module in slot A1 is in warm-up mode or has other problems.
Clock module in slot A12 is in warm-up mode or has other
problems.
Reference signal is in LOS and both clocks have been removed or
are in warm-up.
Only in SDU. Loss of backup clock. Check cable.
No clocks, no output.
VCXO problems, re-seat or replace module.
No clocks or VCXO. Re-seat and check clocks.
Failed to sync with master module in redundant pair.
PQL below provisioned level.
Indicates which output port is in fault (typically shorted). Repair
short and re-enable port.
Module Installed.
Module Removed.
Module Enabled.
Module Disabled.
User request for a module to reboot.
Cannot enable module due to configuration error.
lists the default parameters for the
Description/
12713020-003-2 Revision F.01 – January 2007