Cc Output Module Alarms And Events; Cc Output Module Alarm And Event Messages - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Chapter 6 Alarms and Events

CC Output Module Alarms and Events

CC Output Module Alarms and Events
Table 6-24
lists the alarms and events for the Composite Clock Output module, and
includes the typical response for each alarm or event, it's event number, and a
description or a suggested corrective action. The SNMP MIB trap is listed in the
Alarm/Event/Trap Description column.
Composite Clock Output module alarms.
Table 6-24. CC Output Module Alarm and Event Messages
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
000
Alarm Deprecated, Fault
001
Module Match, Invalid
002
Clk-A, Lost
003
Clk-B, Lost
004
Clk-C, Lost
005
Clk-D, Lost
006
Clk Level, Below
007
Clk Selected, None
008
VCXO, Lost
009
PLL, Unlocked
010
Configuration, Fault
011
IntPortFlt, Active, 40000
012
ExtPortFlt, Active, 40000
013
Hdw Config, Fault
129
Install, CC Output Module
130
Remove, CC Output Module
131
Enable, CC Output Module,
COML
132
Disable, CC Output Module,
COML
133
Restart, in 5 seconds, COML
134
Cannot Enable, CC Output
Module, COML
322 SSU-2000 Technical Reference
Table 6-25
Corrective Action
Alarm not enabled
Redundant configuration mismatch. Re-seat or replace module.
Clock module in slot A1 is in warm-up mode or has other problems.
Clock module in slot A12 is in warm-up mode or has other
problems.
Reference signal is in LOS and both clocks have been removed or
are in warm-up.
Only in SDU. Loss of backup clock. Check cable.
Clock A or B is below output module setting.
No clocks, no output.
VCXO problems, re-seat or replace module.
No clocks or VCXO. Re-seat and check clocks.
Redundant configuration mismatch. Re-seat or replace module.
Driver chip indicated a port fault on port 2 (4000 Hex).
Indication of external port fault on ports 2 and 4 (A000 Hex).
If module is installed in slot previously used by a different module
type, use the CONF xAy REMOVE command.
If problem persists, call Symmetricom Global Services
Module Installed.
Module Removed.
Module Enabled.
Module Disabled.
User request for a module to reboot.
Cannot enable module due to configuration error.
lists the default parameters for the
Description/
12713020-003-2 Revision F.01 – January 2007

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdu-2000

Table of Contents