Retrieve Clock Status - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Retrieve Clock Status

This command returns the clock status, loop mode, current time constant value and
current priority quality level (pql).
Syntax
RTRV-STATUS-CLK:[tid]:[aid]:ctag;
Parameter
[aid]
Response Format
Two message lines are returned if aid = ALL, one for each clock module (if both
modules are installed). One message line is returned for the specified Clock
module. The format for each response line is:
^^^"aid:mstat,mode,tau,pql,(offset),(sigma)" <cr lf>
where:
= the access identifer of the Clock module whose status is being displayed
aid
= module status [OK | SEL | DIS | FLT]
mstat
clock mode
= current time constant in seconds for the clock control loop
tau
= Stratum Level of the clock
pql
= clock frequency offset
offset
= clock frequency sigma value
sigma
Example
SSU_2000 06-06-13 10:45:11
M
100 COMPLD
"S1A01:SEL,LOCK,9000,2,(3.27E-10),(6.75E-10)"
"S1A12:OK,LOCK,1200,2,(1.01E-08),(3.98E-10)"
;
12713020-003-2 Revision F.01 – January 2007
Value
Retrieves the parameters from both Clock modules.
ALL
Retrieves the parameters from the designated Clock
S1A1
module.
S1A12
= [WARM | ACQ | LOCK | HOLD]
Chapter 2 TL1 Reference
Retrieve Clock Status
Description
SSU-2000 Technical Reference
47