OUTPUT xAy FLTMODE {ON|OFF|AUTO}
OUTPUT xAy-z[&&z] {SQUELCH {{0–16}|DISABLE}
OUTPUT xAy-z[&&z] FREQUENCY {8...4096} in 8 kHz steps
OUTPUT xAy SINE {1.544MHZ|6.312MHZ}
OUTPUT xAy 400HZ {ON|OFF}
OUTPUT xAy PLQ {0|{1-16}}
Options are:
ESF|D4
CCS|CAS
E1|2048
ENABLE|DISABLE
LEVEL {ACQ|LOCK}
BYPASS {ON|OFF}
133FT|266FT|399FT|533FT|655FT
CRC {ON|OFF}
ZS {ON|OFF}
SSM {ON|OFF}
SSM {4|5|6|7|8}
DUTYCYCLE
COMPENSATE
FLTMODE
12713020-003-2 Revision F.01 – January 2007
Sets the T1 framing mode: ESF or D4. For DS1 Output
module.
Sets the E1 framing mode: CCS or CAS. For E1 Output
module.
Sets the signal type for the E1/2048 kHz Output module.
Enable or disable the specified output ports. If the module
is one of a redundant pair, this command only affects the
specified module's ports.
Sets the minimum clock level to ACQUIRE or LOCK mode.
The Output module turns off the output port if the level is
below the minimum clock level.
Enables or disables the bypass mode to support Clock C.
Sets the line-length parameters for the output line driver.
For DS1 Output module.
Enables or disables the CRC setting. For E1 and E1/2048
kHz Output modules.
Enables or disables the zero suppression setting. For the
DS1, E1, and E1/2048 kHz Output modules.
Enables or disables the SSM setting. For E1 and E1/2048
kHz Output modules.
Sets the E1 SSM bit position. For E1 and E1/2048 kHz
Output modules.
Sets the Composite Clock output to 63/37 or 50/50 duty
cycles. For CC Output module.
Sets current line compensation for the Composite Clock
output. For CC Output module.
Allows the user to turn the output on or off when the output
level exceeds 2.1v threshold. For 2048 kHz and RS-422
Output modules.