Chapter 6 Alarms and Events

2048 kHz Output Module Alarms and Events

2048 kHz Output Module Alarms and Events
Table 6-22
lists the alarms and events for the 2048 kHz Output module, and
includes the typical response for each alarm or event, it's event number, and a
description or a suggested corrective action. The SNMP MIB trap is listed in the
Alarm/Event/Trap Description column.
2048 kHz Output module alarms.
Table 6-22. 2048 kHz Output Module Alarm and Event Messages
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
000
Alarm Deprecated, Fault
001
Module Match, Invalid
002
Clk-A, Lost
003
Clk-B, Lost
004
Clk-C, Lost
005
Clk-D, Lost
006
Clk Level, Below
007
Clk Selected, None
008
VCXO, Lost
009
PLL, Unlocked
010
Configuration, Fault
011
IntPortFlt, Active, 40000
013
Hdw Config, Fault
014
Squelch, Below Prov
129
Install, 2048 Output Module
130
Remove, 2048 Output
Module
131
Enable, 2048 Output
Module, COML
132
Disable, 2048 Output
Module, COML
133
Restart, in 5 seconds, COML
320 SSU-2000 Technical Reference
Table 6-23
Corrective Action
Alarm not enabled
A redundant pair has one DS1 module and one E1 module.
Replace module.
Clock module in slot A1 is in warm-up mode or has other problems.
Clock module in slot A12 is in warm-up mode or has other
problems.
Reference signal is in LOS and both clocks have been removed or
are in warm-up.
Only in SDU. Loss of backup clock. Check cable.
Clock A or B is below output module setting.
No clocks, no output.
VCXO problems, re-seat or replace module.
No clocks or VCXO. Re-seat and check clocks.
Redundant configuration mismatch. Re-seat or replace module.
Driver chip indicated a port fault on port 2 (4000 Hex).
If module is installed in slot previously used by a different module
type, use the CONF xAy REMOVE command.
If problem persists, call Symmetricom Global Services
Input signal PQL is below user-defined threshold.
Module Installed
Module Removed
Module Enabled
Module Disabled
User request for a module to reboot
lists the default parameters for the
Description/
12713020-003-2 Revision F.01 – January 2007