Chapter 8 Default Settings

Japanese Sine Wave Input Module Default Settings

Japanese Sine Wave Input Module Default Settings
The Japanese Sine Wave Input module maintains factory default and current user
configuration information in nonvolatile memory. This information is retrieved at
power up and is modified by commands from the Communications module. The
factory configuration settings for the JSW Input module are shown in
Table 8-8. Japanese Sine Wave Input Module Configuration Settings
Configuration Setting
Input Frequency
(for unframed signals)
Provisioned PQL
Priority
FREQ Set ClkA
FREQ Set ClkB
FREQ Clear ClkA
FREQ Clear ClkB
Frequency Alarm Mode
MTIE T10 Set Limit1
MTIE T10 Set Limit2
MTIE T100 Set Limit1
MTIE T100 Set Limit 2
MTIE T1K Set Limit 1
MTIE T1K Set Limit 2
MTIE T10K Set Limit 1
MTIE T10K Set Limit 2
MTIE T100K Set Limit 1
MTIE T100K Set Limit 2
MTIE T10 Clear Limit 1
MTIE T10 Clear Limit 2
MTIE T100 Clear Limit 1
MTIE T100 Clear Limit 2
MTIE T1K Clear Limit 1
MTIE T1K Clear Limit 2
354 SSU-2000 Technical Reference
Factory Default
6.312 MHz
4
1
16 000
16 000
12 000
12 000
Major
260
325
440
550
810
1010
880
1100
1600
2000
230
290
400
490
730
910
Range
1.544 MHz | 6.312 MHz
1–16
0–10 (0 = Monitor)
0 to 10 000 000
0 to 10 000 000
0 to 10 000 000
0 to 10 000 000
Ignore | Report | Minor | Major | Critical
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
12713020-003-2 Revision F.01 – January 2007
Table
8-8.