Japan Sine Input Module Alarm Defaults - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Table 6-16. Japan Sine Input Module Alarm and Event Messages (Continued)
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
201
Priority, 5, COML
203
Prov PQL, 5, COML
204
MTIE Err Limit, T100, L1, 550,
COML
206
CSFlt, Off, COML
209
Freq Err Limit, Clk-A, 100, COML
210
Freq Clr Limit, Clk-A, 800, COML
211
MTIE Clr Limit, T100, L1, 500,
COML
212
MTIE Limit, DS1, COML, Setting
213
PBO, Report, COML
214
Freq Tau, Clk-A, 400, COML
224
IoName, Set
251
Err Delay, (0), 10 sec, COML
252
Alm Level, (2), Maj, COML
253
Elevate Time 86400 sec, COML
254
Setup, Save, COML
Table 6-17. Japan Sine Input Module Alarm Defaults
ID
Description
000
LOS
005
MTIE/L1
006
MTIE/L2
007
CS Fault
009
Ref Qualifier
010
Clock PLL
011
Input PLL
012
Phase Hdw
013
FREQ
014
Hdw Config
12713020-003-2 Revision F.01 – January 2007
A user has changed input priority level.
A user has changed input provisioned PQL.
A user has changed input MTIE limits (L1 | L2).
A user has changed input Cesium Fault control.
The frequency error limit settings have been changed.
The frequency clear limit settings have been changed.
The MTIE error limit settings have been changed.
The MTIE clear limit settings have been changed.
Phase Build-out system response has been changed to the
indicated setting.
The frequency TAU limits have been set.
A user has set the IO Name.
An alarm delay time change.
An alarm level change.
An alarm elevation time change.
User defaults have been set and saved.
Alarm Level
Major
Minor
Major
Minor
Minor
Major
Major
Major
Minor
Major
Chapter 6 Alarms and Events
Japan Sine Input Module Alarms and Events
Description/
Corrective Action
SSU-2000 Technical Reference 315

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdu-2000

Table of Contents