PQLTABLE
Use this command to display or change user-defined Priority Quality Level (PQL)
code and text string.
Level 0
Not applicable
Level 1
PQLTABLE
Use this command to display the PQL table setting.
Level 2
Same as Level 1 operation
Level 3
Same as Level 2 operation, with the following additions:
PQLTABLE FACTORY
PQLTABLE pql# [{DS1|E1}] UNUSED
PQLTABLE pql# [{DS1|E1}][SSM n][DESC str] [STD{ON|OFF}]
Use this command to read or set current PQL translation table
information. This table provides the translation from the internal Priority
Quality Level (PQL) to the Synchronization Status Message (SSM) for
the various framing types.
Options are:
FACTORY
Pql#
DS1|E1
UNUSED
SSM n
DESC str
STD {ON|OFF}
Level 4
Same as Level 3 operation
Remarks None
Related
None
236 SSU-2000 Technical Reference
Use this option to set factory defaults for the table. Both
DS1 and E1 are affected.
PQL number for the entry. The range is 1 to 16.
Use this option to specify which entry to affect. If you do not
specify this information, both entries are assumed.
Marks this entry as unused in the table.
Use this option to set the SSM value to use for the framing
type by specifying a hex number, preceded by 0x.
Use this option to set the descriptive text string for this
entry. Use a maximum of 14 characters. You can enclose
the string in double quotes to allow entry of spaces and
lower-case letters.
Use this option to set or clear this entry as the standard
input type. Only standard entries are matched for input.