Mtie Limits For The E1 Input Module; E1 Input Module - Mtie Limits - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Table 8-4. DS1 Input Module – MTIE Limits (Continued)
Set Limit L1
Time (s)
1000
810
10 000
880
100 000
1600

MTIE Limits for the E1 Input Module

Table 8-5
provides MTIE limits for the E1 Input Module configuration settings and
factory defaults and ranges.
Table 8-5. E1 Input Module – MTIE Limits
Set Limit L1
Time (s)
10
80
100
800
1000
1600
10 000
1170
100 000
4260
12713020-003-2 Revision F.01 – January 2007
Set Limit L2
(ns)
(ns)
1010
1100
2000
Set Limit L2
(ns)
(ns)
100
1000
2000
2835
5330
DS1 and E1 Input Module Default Settings
Clear Limit L1
Clear Limit L2
(ns)
730
910
790
990
1440
1800
Clear Limit L1
Clear Limit L2
(ns)
70
90
700
900
1400
1800
2000
2500
3800
4800
SSU-2000 Technical Reference 351
Chapter 8 Default Settings
(ns)