Set E1 Lrm Parameters - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Set E1 LRM Parameters

This command sets the parameters for the specified E1 Line Re-timing Module or
port.
Syntax
SET-PRMTR-LRME1:[tid]:[aid]:ctag::[enable],[slip],[bpv],[flt];
Parameter
aid
enable
slip
bpv
flt
Related Commands
Retrieve E1 LRM
12713020-003-2 Revision F.01 – January 2007
Format
Sets the parameters for the specfied E1 LRM module [or
S1Ay[-z]
port].
Turns the specified module [or port] on or off.
ON | OFF
Sets the slip error threshold in any 24 hour period. If the
0, 1 - 255
set to zero, the accumulated slip error counts are
cleared.
Clears the BPV error count and accumulated error ratio.
CLR | NOP
NOP is an empty field with no operation.
Defines side 1 output generation when the LRU has a
AIS |
loss of signal on side 1 input, loss of all reference
SQUELCH
sources (PLL unlock), or if the input signal's frequency
has exceeded the LRU's ability to retime data.
Fault
Side 1 LOS
PLL Unlock
Excessive Input
Frequency
Parameters, on page 57
Chapter 2 TL1 Reference
Set E1 LRM Parameters
Description
CTA Installed
CTA Not Installed
FLT STRATEGY
FLT STRATEGY
CTA Engaged
FLT STRATEGY
FLT STRATEGY
FLT STRATEGY
SSU-2000 Technical Reference 147