Rs-422 Output Module Default Settings; Japanese Cc Output Module Default Settings; Output Module Configuration; Jcc Output Module Configuration Settings - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Table 8-13. Composite Clock Output Module Configuration (Continued)
Configuration Setting
Duty Cycle
Alarm Elevation Time
Port Delay

RS-422 Output Module Default Settings

The factory default setting and range for all RS-422 Output module software
parameters are listed in
Table 8-14. RS-422 Output Module Configuration
Configuration Setting
Port State
Min Clock
Bypass
Fault Action
Duty Cycle
Alarm Elevation Time
Squelching

Japanese CC Output Module Default Settings

The factory default setting and range for all Japanese Composite Clock Output module
software parameters are listed in
Table 8-15. JCC Output Module Configuration Settings
Configuration Setting
Port Output (Per Port)
Bypass
12713020-003-2 Revision F.01 – January 2007
Factory Default
5/8
86 400 s
3 (1375 feet) in
Normal mode, 7
(275 feet) in
Subtending mode
Table
8-14.
Factory Default
Enabled
Acquire
On
On
50/50
86 400 s
0
Table
8-15.
Factory Default
Enable
Enable
Chapter 8 Default Settings
RS-422 Output Module Default Settings
Range
5/8 or 50/50
60 to 500 000 s, 0 is disabled
0 to 7
(2200, 1925, 1650, 1375, 1100,
825, 550, and 275 feet)
Range
Disabled/Enabled
Acquire/Lock
On/Off
Off/On/Auto
5/8 or 50/50
60 to 500 000 s, 0 is disabled
1 to 16, 0 is disabled
Range
Enable | Disable
Enable | Disable
SSU-2000 Technical Reference 359