E1/2048 Khz Output Module Default Settings; Composite Clock Output Module Default Settings; E1/2048 Khz Output Module Configuration; Composite Clock Output Module Configuration - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Chapter 8 Default Settings

E1/2048 kHz Output Module Default Settings

E1/2048 kHz Output Module Default Settings
The factory default setting and range for all E1/2048 kHz Output module software
parameters are listed in
Table 8-12. E1/2048 kHz Output Module Configuration
Configuration Setting
Signal Type
Framing Mode
PQL Override
Zero suppression
SSM
CRC
SSM Bit Position
Port Output (per port)
Bypass
Port Label (per port)
Alarm Elevation Time
Squelching

Composite Clock Output Module Default Settings

The Composite Clock Output module maintains factory default and current user
configuration settings. The configuration settings for the Composite Clock Output
Module are provided in
Table 8-13. Composite Clock Output Module Configuration
Configuration Setting
Port State
Min Clock
Bypass
Fault Action
358 SSU-2000 Technical Reference
Table
8-12.
Factory Default
E1
CAS
Disabled
On
On
On
8
Enabled
Enable
Null
86 400 s
0
Table
8-13.
Factory Default
Enabled
Acquire
On
On
Range
E1 | 2048
CAS | CCS
0 | 1 – 16, 0 is disabled
On | Off
On | Off
On
4 | 5 | 6 | 7 | 8
Enable | Disable
Enable | Disable
Up to 20 printable characters; 0 is
string terminator
60 to 500 000 s, 0 is disabled
1 to 16, 0 is disabled
Range
Disabled | Enabled
Acquire | Lock
On | Off
Off | On | Auto
12713020-003-2 Revision F.01 – January 2007