Retrieve Rs-422 Output Parameters - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Retrieve RS-422 Output Parameters

This command returns the settings for the RS-422 Output module or port specified
by the aid.
Syntax
RTRV-PRMTR-OUT422:[tid]:[aid]:ctag;
Parameter
[aid]
Response Format
When the aid specifies a port, the response is:
^^^"aid:mode,bypass,fltmode,pstate,frequency"<cr lf>
where:
= port access identifier
aid
= 422
mode
= allow Clock C selection: [ON | OFF]
bypass
= [ON | OFF | AUTO] if output is set to Fault if signal levels fall below the
fltmode
threshold output level
= port enabled state [ON | OFF]
pstate
frequency
512 = 4096 kHz. The resolution of frequency values is 8 kHz.
When the aid specifies a module, the response is:
^^^"aid:mode,bypass,fltmode"<cr lf>
^^^"aid:pstate1,pstate2,...pstate20"<cr lf>
^^^"aid:freq1,freq2,...freq20" <cr lf>
where:
Line 1 contains:
= module access identifier
aid
= 422
mode
= [ON|OFF] for allowing Clock C selection
bypass
= [ON | OFF | AUTO] if output is set to Fault if signal levels fall below the
fltmode
threshold output level
12713020-003-2 Revision F.01 – January 2007
Value
Retrieves the parameters from all RS-422 Output modules
ALL
in the shelf.
Retrieves parameters from the specified RS-422 Output
SxAy[-z]
module [or port].
= [0 | 1 |...| 512] where 0 (Reserved) = 4 kHz, 1 = 8 kHz, 2 = 16 kHz ...
Chapter 2 TL1 Reference
Retrieve RS-422 Output Parameters
Description
SSU-2000 Technical Reference 109

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdu-2000

Table of Contents