Rs-422 Output Module Alarms And Events; Output Module Alarm And Event Messages - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Chapter 6 Alarms and Events

RS-422 Output Module Alarms and Events

RS-422 Output Module Alarms and Events
Table 6-34
lists the alarms and events for the RS-422 Output module, and includes
the typical response for each alarm or event, it's event number, and a description or
a suggested corrective action. The SNMP MIB trap is listed in the Alarm/Event/Trap
Description column.
module alarms.
Table 6-34. RS-422 Output Module Alarm and Event Messages
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
000
Hdw Config, Fault
001
Configuration, Fault
002
Clk-A, Lost
003
Clk-B, Lost
004
Clk-C, Lost
005
Clk-D, Lost
006
Clk Selected, None
007
VCXO, Lost
008
PLL, Unlocked
009
PortFlt, Fault, 40000
129
Install, RS422 Output
Module
130
Remove, RS422 Output
Module
131
Enable, RS422 Output
Module, COML
132
Disable, RS422 Output
Module, COML
133
Restart, in 5 seconds, COML
134
Cannot Enable, RS422
Output Module, COML
203
Bypass, On, COML
205
Frequency, Port[1-4], 16kHz,
COML
332 SSU-2000 Technical Reference
Table 6-35
lists the default parameters for the RS-422 Output
If module is installed in slot previously used by a different module
type, use the CONF xAy REMOVE command.
If problem persists, call Symmetricom Global Services
Redundant configuration mismatch. Re-seat or replace module.
Clock module in slot A1 is in warm-up mode or has other problems.
Clock module in slot A12 is in warm-up mode or has other
problems.
Reference signal is in LOS and both clocks have been removed or
are in warm-up.
Only in SDU. Loss of backup clock. Check cable.
No clocks, no output.
VCXO problems, re-seat or replace module.
No clocks or VCXO. Re-seat and check clocks.
Indicates which output port is in fault (typically shorted). Repair
short and re-enable port.
Module Installed.
Module Removed.
Module Enabled.
Module Disabled.
User request for a module to reboot.
Cannot enable module due to configuration error.
User has changed the Bypass mode.
User has changed the port output frequency.
Description/
Corrective Action
12713020-003-2 Revision F.01 – January 2007