Set MTIE Parameters
This command sets the input MTIE alarm thresholds (EL1 or EL2) and the clear
thresholds (CL1 or CL2) for the specified input. This command is valid for DS1, E1,
Sine, and GPS Input modules.
Syntax
SET-PRMTR-MTIE:[tid]:[aid]:ctag::[threshold],[t10],[t100],[t1k],
[t10k],[t100k];
Parameter
aid
threshold
t10,
t100,
t1k,
t10k,
t100,
Related Commands
Retrieve MTIE
12713020-003-2 Revision F.01 – January 2007
Format
Sets the parameters for the specfied Input module [or
S1Ay[-z]
port].
Sets the input MTIE alarm threshold for the specified
EL1 | EL2
module [or port].
Sets the clear threshold for the specified module [or port].
CL1 | CL2
Sets the error limits in ns for the measurement time
period.
Range = [0 – 60000]
Parameters, on page 92
Chapter 2 TL1 Reference
Set MTIE Parameters
Description