Japan Sine Input Module Alarms And Events; Japan Sine Input Module Alarm And Event Messages - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Chapter 6 Alarms and Events

Japan Sine Input Module Alarms and Events

Japan Sine Input Module Alarms and Events
Table 6-16
lists the alarms and events for the Japan Sine Input module, and
includes the ID number, a typical response for each alarm or event, and a
description or a suggested corrective action. The SNMP MIB trap is listed in the
Alarm/Event/Trap Description column.
Japan Sine Input module alarms.
Table 6-16. Japan Sine Input Module Alarm and Event Messages
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
000
LOS, Active
005
MTIE/L1, Exceeded
006
MTIE/L2, Exceeded
007
CS Fault, Fault
009
Ref Qualifier, Fault
010
Clock PLL, Fault
011
Input PLL, Fault
012
Phase Hdw, Fault
013
FREQ, Fault
014
Hdw Config, Fault
129
Install, J/SW Input Module
130
Remove, J/SW Input Module
131
Enable, J/SW Input Module,
COML
132
Disable, J/SW Input Module,
COML
133
Restart, in 5 seconds, COML
134
Cannot Enable, Input Module,
COML
144
Zero Phase, B, COML
146
Phase Buildout, 334000,
335000, Clk-B
195
Freq, 6.312 MHz, COML
199
Port, Disable, COML
314 SSU-2000 Technical Reference
Table 6-15
lists the default parameters for the
Description/
Corrective Action
Verify signal is connected. To extinguish, disable port.
MTIE limit 1 has been exceeded.
MTIE limit 2 has been exceeded.
Cesium fault
Re-seat module, or correct the input signal to clear the fault.
Re-seat module.
Verify input frequency setting. Re-seat module.
Re-seat module.
Input frequency greater than threshold. Monitor frequency; if
persistent, check source.
Input module can be installed only in the Main shelf.
If module is installed in slot previously used by a different
module type, use the CONF xAy REMOVE command.
If problem persists, call Symmetricom Global Services
The Input module has been installed.
The Input module has been removed.
The Input module has been enabled.
The Input module has been disabled.
Module re-boot.
Internal firmware conflict. Restart module; if the problem
persists, call SGS.
User has forced the phase to be cleared.
Input performed phase buildout and difference in Phase that
cause PBO.
A user has changed input framer setup.
A user has Enabled | Disabled input port.
12713020-003-2 Revision F.01 – January 2007