Other TL1 Commands

The section contains the TL1 commands for activating (enabling), disconnecting
(disabling), removing or restarting modules, and for logging in or out of the
SSU-2000.
ACT-MODULE:[tid]:aid:ctag;
Valid aid codes:
This command activates (enables) a module (not a specific port).
ACT-USER:[tid]:uid:ctag::pwd;
Valid aid codes: none, requires user name instead.
This command logs in the username
CANC-USER:[tid]::ctag;
Valid aid code: None
This command logs off the TL1 user and returns to security level 0.
DISC-MODULE:[tid]:aid:ctag;
Valid aid code;
This command disconnects (disables) a module (not a specific port).
EXIT:[tid]::ctag;
Valid aid code: None
This command logs off the user and returns an EIA-232 port to ASCII mode or
disconnects an Ethernet session to end TL1 communication.
RMV-MODULE:[tid]:aid:ctag;
Valid aid code:
This command removes configuration information for the specified module from the
database of the SSU-2000.
RST-MODULE:[tid]:aid:ctag;
Valid aid code:
This command restarts (reboots) the specified module.
RST-CLOCK:[tid]:aid:ctag;
Valid aid codes:
This command resets the specified clock module via hardware. This reset is more
drastic than the restart in that it does not give the clock time to switch to the
secondary clock if it was the primary clock.