Japanese Cc Input Module Default Settings; Japanese Composite Clock Input Module Configuration Settings - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Table 8-6. GPS Input Module Default Configuration (Continued)Settings
Configuration Setting
MTIE T10K Set Limit 1
MTIE T10K Set Limit 2
MTIE T100K Set Limit 1
MTIE T100K Set Limit 2
MTIE T10 Clear Limit 1
MTIE T10 Clear Limit 2
MTIE T100 Clear Limit 1
MTIE T100 Clear Limit 2
MTIE T1K Clear Limit 1
MTIE T1K Clear Limit 2
MTIE T10K Clear Limit 1
MTIE T10K Clear Limit 2
MTIE T100K Clear Limit 1
MTIE T100K Clear Limit 2

Japanese CC Input Module Default Settings

The Japanese Composite Clock Input module maintains factory default and current
user configuration information in nonvolatile memory. This information is retrieved at
power up and is modified by commands from the Communications module. The
factory configuration settings for the JCC Input module are shown in
Table 8-7. Japanese Composite Clock Input Module Configuration Settings
Configuration Setting
400 Hz
Provisioned PQL
Priority
Alarm Set Delay
Alarm Elevation Time
Port Status
Port Name
12713020-003-2 Revision F.01 – January 2007
Factory Default
880
1100
1600
2000
230
290
400
490
730
9910
790
990
1440
1800
Factory Default
ON
4
1
0 seconds
86 400 seconds
Enabled
None (blank)
Japanese CC Input Module Default Settings
Range
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
0 to 60 000
Range
ON | OFF
1 to 16
1 to 10 (0 = Monitor)
0 to 172 800 seconds
60 to 500 000 seconds, 0 is disabled
Enabled | Disabled
Any string from 0 – 20 characters
SSU-2000 Technical Reference 353
Chapter 8 Default Settings