Tl1 Command Interface - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Chapter 2 TL1 Reference

TL1 Command Interface

Telcordia Technologies (formerly Bellcore) specifies the TL1 command interface for
use as a standard man-machine language for controlling telecommunications
network elements. TL1 provides command sets to support all operation,
administration, maintenance, and provisioning tasks required to maintain and
control an SSU-2000. These tasks include configuring and provisioning security,
monitoring system performance, configuring hardware, locating and handling faults,
and performing equipment diagnosis and testing.
Note: To communicate with the SSU-2000, you must first connect a
terminal to one of the three EIA-232-C serial communication ports and
then provision the Ethernet port. Then you can communicate with the
SSU-2000 using an Ethernet telnet session.
To set up an SSU-2000 port for TL1 communications:
1. Log on to one of the SSU-2000 EIA-232 serial ports using a Supervisor-level (or
higher) user name and password.
2. Set port A, B, or L to TL1 mode. For example, to set the local port (COML) to TL1
mode, at the system prompt, type:
COMM L MODE TL1
The communications mode settings for the COMM A and COMM B ports (located
on the rear panel) are stored in non-volatile RAM, and remain in effect even after
restarting the SSU-2000.
The communications mode settings for the COMM L (local) port (located on the
Communications module) always default to ASCII mode on startup.
3. To close the serial port for TL1 communications, type
ESCape characters from the management terminal. This logs you out and
returns the port to the default communications mode.
When you connect to the SSU-2000 via Ethernet port 2000 (decimal) using a
Telnet-type application, the session opens in TL1 mode. Up to four sessions (users)
can be connected to port 2000 at one time. Once you are connected, you must log
in using the ACT-USER command with a user name and password (if security is
active on the unit).
To log off the user and exit from an Ethernet session, type
Another user can then open a new session by using the ACT-USER command.
To log off the user, exit from an Ethernet session, and close the Ethernet connection
to port 2000, type
then log in using the ACT-USER command.
24
SSU-2000 Technical Reference
. The next user must first connect to port 2000 and
EXIT:::0;
or send three
EXIT::::0;
CANC-USER:::0;
12713020-003-2 Revision F.01 – January 2007
.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sdu-2000

Table of Contents