Cc Input Module Alarms And Events; Composite Clock Input Module Alarm And Event Messages - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Chapter 6 Alarms and Events

CC Input Module Alarms and Events

CC Input Module Alarms and Events
Table 6-8
lists the alarms and events for the Composite Clock Input module, and
includes the typical response for each alarm or event, it's event number, and a
description or a suggested corrective action. The SNMP MIB trap is listed in the
Alarm/Event/Trap Description column.
Composite Clock Input module alarms.
Table 6-8. Composite Clock Input Module Alarm and Event Messages
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
000
LOS, Active
003
BPV, Active
006
Hdw Config, Fault
007
Phase Hdw, Fault
008
Phase 3Sigma, Fault
009
Phase Polarity, Event
129
Install, CC Input Module
130
Remove, CC Input Module
131
Enable, CC Input Module,
COML
132
Disable, CC Input Module,
COML
133
Restart, in 5 seconds, COML
134
Cannot Enable, CC Input
Module, COML
144
Zero Phase, B, COML
146
OutofWindow, Positive BPV
147
Sync Clk-C, Start
148
Operating Mode, Subtending
199
Port, Disable, COML
201
Priority, 5, COML
203
Prov PQL, 5, COML
207
Err Cnt, BPV, 16, COML
304 SSU-2000 Technical Reference
Table 6-9
Corrective Action
No CC signal.
Invalid BPV density.
Input module can be installed only in the Main shelf.
If module is installed in slot previously used by a different module
type, use the CONF xAy REMOVE command.
If problem persists, call Symmetricom Global Services
One of the clock PLLs is not locked.
Check incoming signal quality.
The phase measurements are invalid or missing.
The input signal is unstable.
The Input module has been installed.
The Input module has been removed.
The Input module has been enabled.
The Input module has been disabled.
Module re-boot.
Internal firmware conflict. Restart module; if the problem persists,
call Symmetricom Global Services.
A user has forced the phase to be cleared.
Positive BPV reversed.
Start syncing clock C to selected clock.
Subtending mode is enabled.
A user has Enabled | Disabled input port.
A user has changed input priority level.
A user has changed input provisioned PQL.
Signal Alarm Error Count (LOS, AIS, OOF, BPV, or CRC).
lists the default parameters for the
Description/
12713020-003-2 Revision F.01 – January 2007