*C = critical alarm
** = major alarm
*^ = minor alarm
A^= non-alarm event
(Alarm Correlation Tag) is a six-digit correlation tag that is incremented
atag
each time a message is sent
(Report) indicates an autonomous report
REPT
indicates the cause for the report, such as input signal fault (INP or T1)
AIDTYPE
or module hardware faults (EQPT)
"response message"
message line is:
^^^"[aid]:ntfcncde,condtype,srveff,ocrdat,ocrtm[:condscr]" <cr lf>
where:
–
ntfcncde
alarm or event in an output response or autonomous report, if required.
The notification code is one of these two-character codes:
Critical alarm;
CR
Major alarm;
MJ
Minor alarm:
MN
Cleared alarm;
CL
Event (not an alarm)
NA
–
condtype
message is reporting
–
srveff
response message affects service: SA (Service Affecting response) or
NSA (Not Service Affecting response)
–
ocrdat
YY-MM-DD (year, month, day)
–
ocrtm
format HH:MM:SS (hours, minutes, seconds)
–
condscr
with the alarm or event and which indicates the alarm or event condition
The GR-833 format for an autonomous alarm report is:
<cr lf lf>
^^^sid^date^time <cr lf>
alrmcde^atag^REPT^ALM^[AIDTYPE]<cr lf>
^^^"aid:ntfcncde,condtype,srveff,ocrdat,ocrtm:condscr"<cr lf>
where the terms are identified in this section.
The GR-833 format for an autonomous event report is:
12713020-003-2 Revision F.01 – January 2007
is the response message. The format for the response
(Notification Code) is an optional field that further describes the
(Condition Type) indicates the type of alarm or event that the
(Service Affecting or Not Service Affecting) indicates whether the
(Occurrence Date) indicates the date of occurrence in the format
(Occurrence Time) indicates the time of the occurrence in the
(Condition Description) is an optional text string which is sent
Chapter 2 TL1 Reference
TL1 Command and Response Conventions
SSU-2000 Technical Reference
31