Retrieve E1 Lrm Bpv Data - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Retrieve E1 LRM BPV Data

This command returns the Bipolar Violation data for the specified E1 Line Re-Timing
Module or port.
Syntax
RTRV-DATA-LRME1BPV:[tid]:[aid]:ctag;
Parameter
[aid]
Response Format
^^^"aid:reserved,60srate,24hrate,es,ses,sesr" <cr lf>
where:
= module or port access identifier
aid
reserved
= BPV error rate (floating value) per second in a 60-second window
60srate
= BPV error rate (floating value) per second in an 86400-second
24hrate
window
indicates (integer value) that the BPV accumulates BPV Errored Seconds
es
(BPV-ES) when any seconds have a BPV error
indicates (integer value) that the BPV accumulates BPV Severely Errored
ses
Seconds (BPV-SES) when any seconds have a severely BPV error
= BPV Severely Errored Ratio (floating value)
sesr
Related Commands
12713020-003-2 Revision F.01 – January 2007
Value
Retrieves the current BPV data from all E1 Line
ALL
Re-Timing Modules that are currently active in the entire
shelf.
Retrieves the current BPV data from the specified E1
SxAy[-z]
Line Re-Timing Module [or port].
is a reserved field for future use; no value (empty field) is returned
Chapter 2 TL1 Reference
Retrieve E1 LRM BPV Data
Description
SSU-2000 Technical Reference