Chapter 2 TL1 Reference

Retrieve Clock Parameters

Retrieve Clock Parameters
This command returns the settings for the Clock module designated by the aid.
Syntax
RTRV-PRMTR-CLK:[tid]:[aid]:ctag;
Parameter
[aid]
Response Format
^^^"aid:warmup,mintau,maxtau,clkar,inpswt,inpsel,mintaulimit,maxtau
limit" <cr lf>
where:
= Clock module access identifier
aid
= warmup delay time in s
warmup
= starting time constant in s
mintau
= final time constant value in s
maxtau
= current setting for the Clock Auto-Return mode [ON | OFF]
clkar
= input switch {AR|AS|OFF} for Auto-Return (revertive), Auto-Switch (but
inpswt
not revertive), or no auto switch
= {PRI|PQL} for priority or sync message (PQL) selection of inputs
inpsel
mintaulimit
maxtaulimit
Related Commands
Set Clock
Parameters, on page 137
46
SSU-2000 Technical Reference
Value
Retrieves parameters from all Clock modules in the shelf.
ALL
Retrieves parameters from the specified Clock module.
S1A1 |
S1A12
= minimum tau limit
= maximum tau limit
Description