Symmetricom SSU-2000 Technical Reference page 183

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Example 2: Backup Failed
Input:
CPY-MEM:::TP1000::,,,172.16.20.200;
Response:
"\"172.16.20.200, SSUCONFIG\""
"\"CONFIGURATION BACKUP, PLEASE WAIT\""
"\"1A01 SIZE= 624\""
"\"1A02 SIZE=5272\""
"\"1A06 SIZE=3072\""
"\"1A08 SIZE=1200\""
"\"1A10 SIZE=1224\""
"\"1A12 SIZE= 624\""
"\"CONFIG IMAGE CREATED, SIZE=13788\""
"\"BACKUP CONFIGURATION FAILED, TFTP CONNECTION ERROR\""
SSU_2000 05-10-31 20:13:11
M
100 DENY
SDNR
;
Example 3: Restore Successful
Input:
CPY-MEM:::TP1000::,172.16.20.246;
Response:
"\"172.16.20.246, SSUCONFIG\""
"\"CONFIGURATION RESTORE, PLEASE WAIT\""
"\"1A01 DATA IS SAME AS STORED\""
"\"1A02 SIZE=5272, PASS\""
"\"1A06 SIZE=3072, PASS\""
"\"1A08 SIZE=1224, PASS\""
"\"1A10 SIZE=1224, FAIL\""
"\"1A12 DATA IS SAME AS STORED\""
SSU_2000 05-10-31 20:12:26
M
100 COMPLD
;
Example 4: Restore Failed
Input:
CPY-MEM:::TP1000::,172.16.20.200;
12713020-003-2 Revision F.01 – January 2007
Chapter 2 TL1 Reference
Backing Up and Restoring the Configuration
SSU-2000 Technical Reference 183