Chapter 6 Alarms and Events

Japan CC Output Module Alarms and Events

Japan CC Output Module Alarms and Events
Table 6-30
lists the alarms and events for the Japan Composite Clock Output
module, and includes the typical response for each alarm or event, it's event
number, and a description or a suggested corrective action. The SNMP MIB trap is
listed in the Alarm/Event/Trap Description column.
parameters for the Japan Composite Clock Output module alarms.
Table 6-30. Japan CC Output Module Alarm and Event Messages
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
000
Hdw Config, Fault
001
Configuration, Fault
002
Clk-A, Fault
003
Clk-B, Fault
004
Clk-C, Fault
005
Clk-D, Fault
006
Clk Selected, Fault
007
VCXO, Fault
008
PLL, Fault
009
Redundant, Fault
010
400Hz, Fault
011
4kHz, Fault
012
PortFlt, Fault, 40000
129
Install, J/CC Output Module
130
Remove, J/CC Output
Module
131
Enable, J/CC Output
Module, COML
132
Disable, J/CC Output
Module, COML
133
Restart, in 5 seconds, COML
134
Cannot Enable, J/CC Output
Module, COML
328 SSU-2000 Technical Reference
Corrective Action
If module is installed in slot previously used by a different module
type, use the CONF xAy REMOVE command.
If problem persists, call Symmetricom Global Services
Redundant configuration mismatch. Re-seat or replace module.
Clock module in slot A1 is in warm-up mode or has other problems.
Clock module in slot A12 is in warm-up mode or has other
problems.
Reference signal is in LOS and both clocks have been removed or
are in warm-up.
Only in SDU. Loss of backup clock. Check cable.
No clocks, no output.
VCXO problems, re-seat or replace module.
No clocks or VCXO. Re-seat and check clocks.
Failed to sync with master module in redundant pair.
400 Hz Sync has failed.
4 kHz Sync has failed.
Indicates which output port is in fault (typically shorted). Repair
short and re-enable port.
Module Installed.
Module Removed.
Module Enabled.
Module Disabled.
User request for a module to reboot.
Cannot enable module due to configuration error.
Table 6-31
lists the default