Symmetricom SSU-2000 Technical Reference page 303

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Table 6-7. Basic +SNMPv3 and Basic +NTP + SNMPv3 Communications Module Alarm and Event Messages
(Continued)
Alarm/
Typical Alarm/Event/Trap
Event/
Response
Trap ID
204
SNMPv2 Manager,
INIT,192,5.41.39, COML
206
SNMP Trap, ALM, COML
207
Chg KeepAlive, ALL, 15
minutes, COML
208
Operating Mode,
Subtending, COML
209
Notification, V3, COML
210
Login Event, Enable, COML
211
TL1 Format, GR831, COML
212
SNMPv3 User, ADD, id=1,
COML
213
SNMPv3 Manager,
INIT,192,5.41.39, COML
251
Err Delay, (1), 300 sec,
COML
252
Alm Level, (2), Rep, COML
253
Elevate Time, 3600 sec,
COML
254
Setup, Save, COML
12713020-003-2 Revision F.01 – January 2007
Corrective Action
An SNMP Manager has been initialized at the IP address shown.
The SNMP Trap Port has been set to send traps on alarms only by
A user.
The Keep Alive timer has been set to the interval shown.
A user has changed the operating mode.
A user has changed the notification format.
A user has changed whether login events are stored.
A user has changed the TL1 format to the specified value.
An SNMP user has been added to the user table in the position
shown.
An SNMP Manager has been initialized at the IP address shown.
A user has changed the alarm delay time.
An alarm level change.
A user has changed the alarm elevation time.
A user has saved the setup to the user default.
Chapter 6 Alarms and Events
Communication Module Alarms and Events
Description/
SSU-2000 Technical Reference 303

Advertisement

Table of Contents
loading

Related Products for Symmetricom SSU-2000

This manual is also suitable for:

Sdu-2000

Table of Contents