Retrieve Alarm Parameters - Symmetricom SSU-2000 Technical Reference

Synchronization supply unit and synchronization distribution unit
Hide thumbs Also See for SSU-2000:
Table of Contents

Advertisement

Chapter 2 TL1 Reference

Retrieve Alarm Parameters

Retrieve Alarm Parameters
This command returns the alarm settings for the specified module, or ALL alarms if
no aid is specified.
Syntax
RTRV-PRMTR-ALARM:[tid]:[aid]:ctag;
Parameter
[aid]
Response Format
^^^"aid:almnum,level,startdelay,cleardelay"<cr lf>
where:
= module or port access identifier
aid
= alarm number
almnum
= Ignore, Report, Minor, Major, or Critical: [IGN|RPT|MIN|MAJ|CRT]
level
startdelay
cleardelay
are reported only if they are settable for the alarm; otherwise they are reported as
IMMED (immediate).
Related Commands
Retrieve All
40
SSU-2000 Technical Reference
Value
Retrieves all the alarm parameters from the shelf.
ALL
Retrieves alarm parameters from the specified module [or
SxAy[-z]
port].
= delay time or errored seconds count for start of the alarm
= cleared seconds count for clearing of the alarm. Delay numbers
Alarms, on page 42
Description
12713020-003-2 Revision F.01 – January 2007