Checking Errors With Windows; A-5-1 Industrial Pc Support Utility; A-5-2 Windows Issues And Troubleshooting; Industrial Pc Support Utility - Omron NY532-5400 Troubleshooting Manual

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

A-5

Checking Errors with Windows

This section describes how to use Windows to check errors that occur in the NY-series Industrial PC or
Windows. Take necessary measures if an error occurs.
A-5-1

Industrial PC Support Utility

You can check status of the NY-series Industrial PC with the Industrial PC Support Utility.
Additional Information
For details on the Industrial PC Support Utility, refer to the NY-series Industrial Panel PC / Indus-
trial Box PC Setup User's Manual (Cat. No. W568).
System Status Tab Page
The following table shows errors and corrections you can check with the System Status Tab Page of the
Industrial PC Support Utility.
Item
Internal temperature
Fan revolution
Fan status
Battery status
For how to replace the fan or battery, refer to NY-series Industrial Box PC Hardware User's Manual
(Cat. No. W556) or NY-series Industrial Panel PC Hardware User's Manual (Cat. No. W557).
Controller Status Tab Page
With the Controller Status Tab Page of the Industrial PC Support Utility, you can check Controller errors
and error status of the EtherNet/IP port. Refer to 1-3-2 Checking for Non-fatal Errors on page 1-17.
A-5-2

Windows Issues and Troubleshooting

Issues and errors that occur in Windows are reported by the Windows Action Center, Pop Up windows,
etc. You can check Windows events with the Windows Event Viewer.
Windows Action Center
The Windows Action Center indicates security and maintenance issues.
Take necessary measures if a warning or error is displayed.
NY-series Troubleshooting Manual (W564)
Error
The temperature inside the Indus-
trial PC exceeded the specified
value.
The speed of the fan dropped.
The message Low Revolution
Speed is displayed.
The voltage of the Battery has
dropped.
Correction
Improve the environment so that the ambient
operating temperature does not exceed the
specified value.
If there is any material that is interfering with
fan operation, remove it. Replace the fan if the
speed dropped while there is no obstacle.
Replace the Battery.