3 Error Descriptions and Corrections
Event name
Permitted Following Error Out of Range
The parameter specified for the PermittedDeviation input variable to a motion control instruction is out of
Meaning
range.
PLC Function Module
Source
Error attri-
Level
butes
Effects
User program
Variable
System-
defined
_MC_COM.MFaultLvl.Active
variables
Assumed cause
Instruction input parameter
Cause and
exceeded the valid range of the
correction
input variable.
Attached Information 1: Error Location
Attached Information 2: Error Location Details (Rung Number). For a program section, the rung number
from the start of the section is given. For ST, the line number is given.
Attached
Attached Information 3: Names of the Instruction and Instruction Instance Where the Error Occurred. If
information
there is more than one possible instruction, information is given on all of them. Nothing is given if the
instruction cannot be identified.
Attached Information 4: Expansion Error Code (ErrorIDEx)
Precautions/
If a program is changed after an error occurs, the attached information that is displayed may not be cor-
Remarks
rect.
3-264
Source details
Observation
Recovery
Continues.
Operation
Data type
BOOL
Correction
Correct the parameter so that the
valid range of the input variable is
not exceeded for the relevant
instruction.
Event code
5401 5488 hex
Instruction
Detection
timing
---
Log category
The relevant instruction will end according to speci-
fications.
Name
MC Common Minor Fault Occur-
rence
Prevention
Set the input parameter to the
instruction so that the valid range
of the input variable is not
exceeded.
NY-series Troubleshooting Manual (W564)
At instruction
execution