Omron NY532-5400 Troubleshooting Manual page 103

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

Event code
Event name
5401440D hex
File or Directory
Name Is Too Long
5401440E hex
Shared Folder
Access Failed
54014411 hex
Slave Backup
Failed
54014800 hex
Device Error
Received
54014801 hex
Specified Unit
Does Not Exist
54014802 hex
Message Process-
ing Limit Exceeded
54014803 hex
Specified Unit Sta-
tus Error
54014804 hex
Too Many Simulta-
neous Instruction
Executions
54014805 hex
Communications
Timeout
54014806 hex
Invalid Mode
54014807 hex
I/O Power OFF
Status
54014808 hex
Verification Error
54015420 hex
Electronic Gear
Ratio Numerator
Setting Out of
Range
54015421 hex
Electronic Gear
Ratio Denomina-
tor Setting Out of
Range
NY-series Troubleshooting Manual (W564)
Meaning
The file name or directory
• The file name or direc-
name that was specified for
an instruction is too long.
The access to the shared
• The shared folder is
folder failed.
A slave backup operation
• A slave backup opera-
failed.
An error response from the
• An error response
device was received.
The specified Unit does not
• The IO-Link master is
exist.
An instruction cannot be
• An instruction cannot
executed because the IO-
Link master is processing
the message from another
application.
The specified Unit is not in
• The specified Unit is
a condition to receive mes-
sages.
The number of instructions
• More than 32 NX mes-
that can be simultaneously
executed was exceeded.
A timeout occurred in com-
• The communications
munications.
• The cable for Ether-
• Noise
• Device failure
The specified IO-Link mas-
• The specified IO-Link
ter port is not the IO-Link
mode.
The I/O power is not sup-
• The I/O power is not
plied to the specified IO-
Link master port.
The specified IO-Link mas-
• The specified IO-Link
ter port had a verification
error or a communications
error.
The parameter specified for
• Instruction input
the RatioNumerator input
variable to a motion control
instruction is out of range.
The parameter specified for
• Instruction input
the RatioDenominator input
variable to a motion control
instruction is out of range.
3 Error Descriptions and Corrections
Assumed cause
Maj
Prt
tory name that was
specified for the
instruction to create is
too long.
corrupted.
tion failed.
from the device was
received.
not connected to or
mounted on the speci-
fied position.
be executed because
the IO-Link master is
processing the mes-
sage from another
application (an instruc-
tion execution or a tool
connection).
not in a condition to
receive messages.
sage instructions and
EtherCAT communica-
tions instructions were
executed at the same
time.
timeout time is shorter
than the message
response time.
CAT or for IO-Link is
broken.
master port is not the
IO-Link mode.
supplied to the speci-
fied IO-Link master
port.
master port had a veri-
fication error or a com-
munications error.
parameter exceeded
the valid range of the
input variable.
parameter exceeded
the valid range of the
input variable.
Level
Refer-
ence
Min
Obs
Info
S
page 3-177
S
page 3-177
S
page 3-178
S
page 3-178
S
page 3-179
S
page 3-180
S
page 3-180
S
page 3-181
S
page 3-182
S
page 3-183
S
page 3-183
S
page 3-184
S
page 3-184
S
page 3-185