Omron NY532-5400 Troubleshooting Manual page 134

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

3 Error Descriptions and Corrections
Event name
Firmware Configuration Mismatch
Meaning
An inconsistency was detected in the software which configures the firmware.
PLC Function Module
Source
Error attri-
Level
butes
Effects
User program
System-
Variable
defined vari-
None
ables
Assumed cause
The firmware upgrade is not com-
pleted.
Cause and
correction
The firmware was partially
restored using the Rescue disk.
An HDD or a SSD was replaced.
Attached
Attached information 1: The name and version of the software in which an inconsistency occurred.
information
Precau-
None
tions/Remarks
*1 Refer to I/O Operation for Major Fault Level Controller Errors on page 1-14 for details.
Event name
PLC System Processing Error
Meaning
A fatal error was detected in the PLC Function Module.
PLC Function Module
Source
Error attri-
Level
butes
Effects
User program
System-
Variable
defined
None
variables
Assumed cause
Cause and
An error occurred in the software. Contact your OMRON represen-
correction
Attached
Attached information 1: System information
information
Precautions/
None
Remarks
* For details, refer to I/O Operation for Major Fault Level Controller Errors on page 1-14.
3-58
Source details
Major fault
Recovery
Stops.
Operation
Data type
---
Correction
Upgrade the firmware again.
Restore the whole system using
the Rescue disk.
Source details
Major fault
Recovery
Stops.
Operation
Data type
---
Correction
tative.
Event code
10120000 hex
None
Detection tim-
ing
Cycle the
Log category
power supply.
*1
Stops.
Name
---
Prevention
None
None
Event code
4003 0000 hex
None
Detection
timing
Cycle the
Log category
power supply.
*
Stops.
Name
---
Prevention
None
NY-series Troubleshooting Manual (W564)
At power ON or
Controller reset
System
Continuously
System

Advertisement

Table of Contents
loading

Table of Contents