Omron NY532-5400 Troubleshooting Manual page 312

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

3 Error Descriptions and Corrections
Event name
Illegal Master Axis Specification
Meaning
The axis that is specified for the Master input variable to a motion control instruction is not correct.
PLC Function Module
Source
Error attri-
Level
butes
Effects
User program
Variable
System-
_MC_COM.MFaultLvl.Active
defined
variables
_MC_AX[*].MFaultLvl.Active
Assumed cause
An axis does not exist for the vari-
able specified for the Master input
variable to the instruction.
The axis that was specified for
the Master input variable to the
MC_Phasing (Shift Master Axis
Cause and
Phase) instruction is not the mas-
correction
ter axis for syncing.
The master axis and a slave axis
are not assigned to the same
task.
Attached Information 1: Error Location
Attached Information 2: Error Location Details (Rung Number). For a program section, the rung number
from the start of the section is given. For ST, the line number is given.
Attached
Attached Information 3: Names of the Instruction and Instruction Instance Where the Error Occurred. If
information
there is more than one possible instruction, information is given on all of them. Nothing is given if the
instruction cannot be identified.
Attached Information 4: Expansion Error Code (ErrorIDEx)
Precautions/
If a program is changed after an error occurs, the attached information that is displayed may not be cor-
Remarks
rect.
3-236
Source details
Observation
Recovery
Continues.
Operation
Data type
BOOL
BOOL
Correction
Correct the instruction so that the
variable exists for the axis that
was specified for the instruction.
Correct the variable that is input
to the Master input variable of the
MC_Phasing (Shift Master Axis
Phase) instruction to the axis
variable that is specified as the
master axis of the synchronized
control instruction.
Assign the axes that are input to
the Master and Slave input vari-
ables to the instruction to the
same task.
Event code
5401 5462 hex
Instruction
Detection
timing
---
Log category
The relevant instruction will end according to speci-
fications.
Name
MC Common Minor Fault Occur-
rence
Axis Minor Fault Occurrence
Prevention
Specify a variable that exists
when specifying a variable for an
input parameter to an instruction.
Set the variable that is input to
the Master input variable of the
MC_Phasing (Shift Master Axis
Phase) instruction to the axis
variable that is specified as the
master axis of the synchronized
control instruction.
Specify axes that are assigned to
the same tasks for the master
and slave axes.
NY-series Troubleshooting Manual (W564)