Event name
Aborted Cam Table Used
A cam data variable that was aborted during generation was specified for the CamTable input variable to
Meaning
an instruction.
PLC Function Module
Source
Error attri-
Level
butes
Effects
User program
Variable
System-
_MC_COM.MFaultLvl.Active
defined
variables
_MC_AX[*].MFaultLvl.Active
Assumed cause
A cam data variable that was
aborted during generation due to
an error in the MC_Generate-
CamTable (Generate Cam Table)
Cause and
instruction was specified for the
correction
CamTable input variable to the
instruction.
Attached Information 1: Error Location
Attached Information 2: Error Location Details (Rung Number).
For a program section, the rung number from the start of the section is given. For ST, the line number is
Attached
given.
information
Attached Information 3: Names of the Instruction and Instruction Instance Where the Error Occurred. If
there is more than one possible instruction, information is given on all of them. Nothing is given if the
instruction cannot be identified.
Attached Information 4: Expansion Error Code (ErrorIDEx)
Precautions/
If a program is changed after an error occurs, the attached information that is displayed may not be cor-
Remarks
rect.
NY-series Troubleshooting Manual (W564)
Source details
Observation
Recovery
Continues.
Operation
Data type
BOOL
BOOL
Correction
Check the ErrorID (error code),
ErrorParameterCode (parameter
detail code), and ErrorNode-
PointIndex (node point element
number) output variables from
the MC_GenerateCamTable
(Generate Cam Table) instruc-
tion and correct the program so
that correct cam data variables
are created.
3 Error Descriptions and Corrections
Event code
54015743 hex
Instruction
Detection
timing
---
Log category
The relevant instruction will end according to speci-
fications.
Name
MC Common Minor Fault Occur-
rence
Axis Minor Fault Occurrence
Prevention
Write the program so that the
MC_GenerateCamTable (Gener-
ate Cam Table) instruction cre-
ates correct cam data variables.
Or, write the program so that the
relevant instruction is executed
only when the MC_Generate-
CamTable (Generate Cam Table)
instruction ends normally.
At instruction
execution
System
3
3-307