Omron NY532-5400 Troubleshooting Manual page 377

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

Event name
Cam Node Setting Out of Range
The parameter specified for the CamNodes input variable to a motion control instruction is outside of the
Meaning
valid range.
PLC Function Module
Source
Error attri-
Level
butes
Effects
User program
Variable
System-
defined
_MC_COM.MFaultLvl.Active
variables
Assumed cause
The parameter specified for the
CamNodes input variable to the
Cause and
instruction is out of range for the
correction
input variable.
Attached Information 1: Error Location
Attached Information 2: Error Location Details (Rung Number).
For a program section, the rung number from the start of the section is given. For ST, the line number is
Attached
given.
information
Attached Information 3: Names of the Instruction and Instruction Instance Where the Error Occurred. If
there is more than one possible instruction, information is given on all of them. Nothing is given if the
instruction cannot be identified.
Attached Information 4: Expansion Error Code (ErrorIDEx)
Precautions/
If a program is changed after an error occurs, the attached information that is displayed may not be cor-
Remarks
rect.
NY-series Troubleshooting Manual (W564)
Source details
Observation
Recovery
Continues.
Operation
Data type
BOOL
Correction
Correct the parameter so that the
valid range of the input variable is
not exceeded for the instruction.
Confirm which parameter
exceeded the range in the
attached information.
3 Error Descriptions and Corrections
Event code
5401573D hex
Instruction
Detection
timing
---
Log category
The relevant instruction will end according to speci-
fications.
Name
MC Common Minor Fault Occur-
rence
Prevention
Set the input parameter to the
instruction so that the valid range
of the input variable is not
exceeded.
At instruction
execution
System
3
3-301