3 Error Descriptions and Corrections
Event name
Execution ID Setting Out of Range
Meaning
The parameter specified for the ExecID input variable to a motion control instruction is out of range.
PLC Function Module
Source
Error attri-
Level
butes
Effects
User program
System-
Variable
defined
_MC_AX[*].MFaultLvl.Active
variables
Assumed cause
The parameter specified for the
Cause and
ExecID input variable to the
correction
instruction is out of range for the
input variable.
Attached Information 1: Error Location
Attached Information 2: Error Location Details (Rung Number).
For a program section, the rung number from the start of the section is given. For ST, the line number is
given.
Attached
information
Attached Information 3: Names of the Instruction and Instruction Instance Where the Error Occurred. If
there is more than one possible instruction, information is given on all of them. Nothing is given If the
instruction cannot be identified.
Attached Information 4: Expansion Error Code (ErrorIDEx)
Precautions/
If a program is changed after an error occurs, the attached information that is displayed may not be cor-
Remarks
rect.
Event name
Position Offset Out of Range
Meaning
The parameter specified for the OffsetPosition input variable to a motion control instruction is out of range.
PLC Function Module
Source
Error attri-
Level
butes
Effects
User program
System-
Variable
defined
_MC_AX[*].MFaultLvl.Active
variables
Assumed cause
The instruction input parameter
Cause and
exceeded the range of signed 40-
correction
bit data when it was converted to
pulses.
Attached Information 1: Error Location
Attached Information 2: Error Location Details (Rung Number). For a program section, the rung number
from the start of the section is given. For ST, the line number is given.
Attached
Attached Information 3: Names of the Instruction and Instruction Instance Where the Error Occurred. If
information
there is more than one possible instruction, information is given on all of them. Nothing is given If the
instruction cannot be identified.
Attached Information 4: Expansion Error Code (ErrorIDEx)
Precautions/
If a program is changed after an error occurs, the attached information that is displayed may not be cor-
Remarks
rect.
3-308
Source details
Observation
Recovery
Continues.
Operation
Data type
BOOL
Correction
Correct the program so that the
input parameter specified for the
ExecID input variable to the
instruction is within the setting
range.
Source details
Observation
Recovery
Continues.
Operation
Data type
BOOL
Correction
Correct the parameter so that the
valid range of the input variable is
not exceeded for the relevant
instruction.
Event code
5401 5749 hex
Instruction
Detection
timing
---
Log category
The relevant instruction will end according to speci-
fications.
Name
Axis Minor Fault Occurrence
Prevention
Create the program so that the
input parameter specified for the
ExecID input variable to the
instruction is within the setting
range.
Event code
5401 574A hex
Instruction
Detection
timing
---
Log category
The relevant instruction will end according to speci-
fications.
Name
Axis Minor Fault Occurrence
Prevention
Set the input parameter to the
instruction so that the valid range
of the input variable is not
exceeded.
NY-series Troubleshooting Manual (W564)
At instruction
execution
System
At instruction
execution
System

Advertisement