Omron NY532-5400 Troubleshooting Manual page 564

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

3 Error Descriptions and Corrections
Number of Array Elements in Switch Structure Vari-
Event name
able Out of Range
The number of elements in an array in the structure variable that is specified in the Switches in-out vari-
Meaning
able to a motion control instruction is out of range.
Motion Control Function Module
Source
Error attri-
Level
butes
Effects
User program
System-
Variable
defined
_MC_AX[*].Obsr.Active
variables
Assumed cause
The number of elements in an
Cause and
array of the structure variable that
correction
was specified for the in-out vari-
able of the instruction is out of
range.
Attached
None
information
Precautions/
None
Remarks
Number of Array Elements in Output Signal Struc-
Event name
ture Variable Out of Range
The number of elements in an array in the structure variable that is specified in the Outputs in-out variable
Meaning
to a motion control instruction is out of range.
Motion Control Function Module
Source
Error attri-
Level
butes
Effects
User program
System-
Variable
defined
_MC_AX[*].Obsr.Active
variables
Assumed cause
The number of elements in an
Cause and
array of the structure variable that
correction
was specified for the in-out vari-
able of the instruction is out of
range.
Attached
None
information
Precautions/
None
Remarks
3-488
Source details
Observation
Recovery
Continues.
Operation
Data type
BOOL
Correction
Correct the number of elements
in the array in the structure vari-
able that is specified for the in-out
variable of the relevant instruction
so that it is in the valid range.
Source details
Observation
Recovery
Continues.
Operation
Data type
BOOL
Correction
Correct the number of elements
in the array in the structure vari-
able that is specified for the in-out
variable of the relevant instruction
so that it is in the valid range.
572B0000 hex
Event code
Axis
Detection
timing
Error reset
Log category
Not affected.
Name
Axis Observation Occurrence
Prevention
Make sure that the number of ele-
ments in the array in the structure
variable that is specified for the
in-out variable of the relevant
instruction is in the valid range.
572C 0000 hex
Event code
Axis
Detection
timing
---
Log category
Not affected.
Name
Axis Observation Occurrence
Prevention
Make sure that the number of ele-
ments in the array in the structure
variable that is specified for the
in-out variable of the relevant
instruction is in the valid range.
NY-series Troubleshooting Manual (W564)
At instruction
execution
System
At instruction
execution
System

Advertisement

Table of Contents
loading

Table of Contents