1 Overview of Errors
1-3-6
Errors Related to the EtherCAT Master Function Module
This section describes the errors that are related to the EtherCAT Master Function Module.
Locations of Errors in the EtherCAT Master Function Module
Errors can occur internally in the EtherCAT Master Function Module, or they can occur in the built-in
EtherCAT port or in EtherCAT slaves.
NY-series Controller
EtherCAT Master
Function Module
Built-in EtherCAT port
EtherCAT
EtherCAT
slaves
Additional Information
If any one of the following errors occurs at the same time for more than one slave, only the error
for the slave that is closest to the master is recorded in the event log. The same error is not
recorded in the event log for slaves that are connected further from the master.
• Network Configuration Verification Error
• Process Data Communications Errors (when caused by a disconnected cable)
• Slave Node Address Duplicated
• Slave Initialization Error
1-30
Sysmac Studio
Error information
HMI
Or
NY-series Troubleshooting Manual (W564)