Event name
Cannot Change Axis Use
The MC_ChangeAxisUse (Change Axis Use) instruction was executed in a way that would cause the
Meaning
maximum number of used real axes or the maximum number of used motion control servo axes to be
exceeded.
Motion Control Function Module
Source
Error attri-
Level
butes
Effects
User program
Variable
System-
defined
_MC_COM.MFaultLvl.Active
variables
Assumed cause
The MC_ChangeAxisUse
(Change Axis Use) instruction
was executed in a way that would
cause the maximum number of
Cause and
used real axes to be exceeded.
correction
The MC_ChangeAxisUse
(Change Axis Use) instruction
was executed in a way that would
cause the maximum number of
used motion control servo axes to
be exceeded.
Attached
None
information
Precautions/
None
Remarks
NY-series Troubleshooting Manual (W564)
Source details
Minor fault
Recovery
Continues.
Operation
Data type
BOOL
Correction
Correct the program so that the
maximum number of real axes
used by the CPU Unit is not
exceeded.
Correct the program so that the
maximum number of used motion
control servo axes that can be
used by the CPU Unit is not
exceeded.
3 Error Descriptions and Corrections
Event code
57030000 hex
MC common
Detection
timing
Error reset
Log category
Not affected.
Name
MC Common Minor Fault Occur-
rence
Prevention
Write the program so that the
maximum number of real axes
used by the CPU Unit is not
exceeded.
Write the program so that the
maximum number of used motion
control servo axes that can be
used by the CPU Unit is not
exceeded.
At instruction
execution
System
3
3-465