Omron NY532-5400 Troubleshooting Manual page 692

Ny-series
Hide thumbs Also See for NY532-5400:
Table of Contents

Advertisement

Appendix
Event code
Event name
80240000 hex
NX Unit Clock
Not Synchro-
nized Error
65140000 hex
Over Range
65150000 hex
Under Range
80220000 hex
NX Message
Communica-
tions Error
90400000 hex
Event Log
Cleared
A-46
Meaning
Assumed cause
An error occurred in
• There is a hardware
the clock informa-
error in the NX Unit.
tion between the
• There is a hardware
EtherCAT Coupler
error in the EtherCAT
Unit and the NX
Coupler Unit.
Unit.
The input signal
• Wiring with the load cell
from the load cell
is not connected.
exceeded the upper
• Wiring with the load cell
limit of the input
is broken.
conversion range.
• EXC+ terminal and
EXC- terminal are
short-circuited.
• Load cell failure.
• A load cell with which
the rated output
exceeds the input range
of the Load Cell Input
Unit is used.
• A load that exceeds the
rated capacity is applied
to the load cell.
• Noise
The input signal
• Wiring with the load cell
from the load cell
is not connected.
went below the
• Wiring with the load cell
lower limit of the
is broken.
input conversion
• EXC+ terminal and
range.
EXC- terminal are
short-circuited.
• Load cell failure.
• A load cell with which
the rated output
exceeds the input range
of the Load Cell Input
Unit is used.
• A load that exceeds the
rated capacity is applied
to the load cell.
• Noise
An error was
For the NX bus of CPU
detected in mes-
Units
sage communica-
• The message communi-
tions and the
cations load is high.
message frame was
For Communications Cou-
discarded.
pler Units
• The message communi-
cations load is high.
• The communications
cable is disconnected or
broken.
• Message communica-
tions were cutoff in com-
munications.
The event log was
• The event log was
cleared.
cleared by the user.
Level
Maj
Prt
Min
Obs
Info
S
U
S
U
S
S
S
NY-series Troubleshooting Manual (W564)
Reference
W565
W565
W565
W565
W565